Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be on display in the machine room 10/3/2022
A17.1-1996 : Elevators 2.11 - Disconnecting Means and Control 210.4 A major alteration was performed alteration was performed on this elevator in 2005. At the time of the alteration, the adopted code was A17.1 1996 which required that the elevator be brought up to A17.3 and A17.1 1996. This requires that a 110 volt disconnect be installed in the elevator machine room to remove power to the elevator cab lights. There is no 110 volt disconnect in the machine room. Install a 110 volt disconnect for the elevator cab lights that meet or exceed the A17.1 1996 requirements. 9/25/2020
MO Minimum : Elevators (I) - Pits (I)1 Clean the pit. 11/19/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder packing is worn and leaking, repair as needed. 11/19/2024
MO Minimum : Elevators (A) - Hoistways (A)6 First floor door interlock (hoistway) missing cover, replace as needed 11/17/2022
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) First floor door lock (hoistway) missing cover 11/17/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Lighting in car shall have 2 bulbs. Ceiling panels in car are open egg crate type, providing no protection for passengers in event of bulb breakage, replace with solid type panels or install plastic tubes and end caps on bulbs 10/3/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate place current operating certificate in machine room 9/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Provide existing emergency lights and bell to work 9/22/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Provide existing emergency lights and bell to work 9/22/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Provide existing phone to work with 24/7 support 9/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Provide existing phone to work with 24/7 support 9/22/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 Provide machine room door to be self closing. 11/19/2024
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) The elevator machine room door shall be self-closing/self-locking and shall be operable from the interior space without the use of a key. 9/25/2020
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) There is no fire extinguisher in the machine room, as required. Provide an ABC type extinguisher of proper size for the room. 9/25/2020