Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Replace electrical conduit on side of car 7/25/2018
conversion conversion n/a Cover junction box on car top 7/25/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Fire extinguisher needs to be serviced. 12/11/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide a current tested fire extinguisher in the elevator machine room. 3/8/2022
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing and self-locking. 3/8/2022
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) A permanent lighting fixture shall be provided in all pits to provide illumination of not less then 5 ftc at the pit floor. 3/8/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Provide a code compliant MCP including onsite documents. 3/8/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 3/7/2022
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)4 x x The movement of the safety drum rope, starting from a fully retracted position, must not exceed 42 inches (it pulled out approximately 120 inches) before the safety shoes contact the rail. Elevator Red Tagged. 10/10/2022
MO Minimum : Elevators (I) - Pits (I)1 Water and oil shall not be allowed to accumulate on the pit floors. Note: The pit floor is covered with several inches of water. 3/14/2023
MO Minimum : Elevators (A) - Hoistways (A)16 All electrical wiring in the hoistway shall be enclosed in metal conduit, flexible conduit, metal raceway, or be in compliance with NFPA70. Note: There are bare wires running throughout the hoistway. 3/14/2023
MO Minimum : Elevators (A) - Hoistways (A)16 The missing junction box covers in the hoistway shall be replaced. 3/14/2023
MO Minimum : Elevators (A) - Hoistways (A)12 The penetrations in the hoistway shall be sealed with approved materials. 3/14/2023
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The fluorescent pit light shall be operational and permanently wired. Note: The fixture is currently attached to a cord which runs through a hole in the hoistway wall and is plugged into an extension cord. 3/14/2023
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)5 Properly secure cab lights to ceiling.