A17.1-1996 : Elevators
|
2.3 - Lighting and receptacles
|
101.5a Lighting
|
|
|
Repair Machine Room Lights
|
9/21/2022
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
102
|
x
|
|
Clean pit
|
2/28/2020
|
A17.1-1996 : Elevators
|
1.4 - Sills and car floor
|
108.1
|
|
|
Replace cracked car floor tile at car entrance
|
9/21/2022
|
A17.1-1996 : Elevators
|
1.7 - Car door or gate
|
204.4
|
|
|
Adjust car door operator excess door closing force
|
9/21/2022
|
A17.1-1996 : Elevators
|
2.13 - Governor,overspeed switch and seal
|
206
|
x
|
x
|
Adjust governor--safeties in order to complete 5 year test
|
10/13/2021
|
A17.1-1996 : Elevators
|
3.20 - Governor rope
|
206.5
|
x
|
|
REplace hoist ropes within 30 days red rouge & reduced diameter
|
2/28/2020
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.2-211.8
|
x
|
x
|
Repair fire service car will not respond on phase 1 with car doors open or phase 2 will not revert back to phase 1 with doors open
|
2/28/2020
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current state certificate in machine room
|
9/21/2022
|
A17.1-2016 : Elevators
|
3.23 - Suspension Means
|
8.11.2.1.3(cc)
|
x
|
|
Replace hoist ropes--red rouge--reduced diameter within 30 days
|
10/13/2021
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.6.11.1 Monthly Test and Log
|
|
|
Perform monthly fire service and document on log in machine room
|
9/21/2022
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Repair Fire Service a. Car will not recall on phase 1 when car doors are open b. car doors will not come completely close and recall when turning phase 2 off in car
|
2/8/2018
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Fire Service Failed Will not return to recall level when keyed pff Phase II
|
12/11/2018
|