Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.16 - Rated load, platform area, and data plate 1001.2(a)(16) A capacity plate shall be provided in the car. 7/8/2021
conversion conversion n/a Clean Drip Pan (remove oil) in machine room 8/31/2018
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. 7/8/2021
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) Machine room shall not be used for storage. There is also a sink in the machine room. Remove the sink or separate equipment per code. Customer may need to apply for a variance.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 11/19/2024
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x The means to restrict opening of the car door shall be operational. 8/11/2021
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up-to-date operating certificate required in the machine room.
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 Water pipe above the hydraulic tank shall be guarded or guttered to divert any potential leaks away from tank.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. 7/8/2021