MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
1/5/21 : Car Door restrictor shall work. Front and rear (REINSPECTION REQUIRED)
|
8/11/2021
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
1/5/21: Suspension rope tails shall be shortened and clamped according to1996-103.4
|
8/11/2021
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
|
1/5/21: F(2) Bottom limit switch shall work. REINSPECTION REQUIRED
|
8/11/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
1/5/21. Replace car door gibbs, cutting into sill.
|
4/16/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
1/5/21 : Car Door restrictor shall work. Front and rear (REINSPECTION REQUIRED)
|
8/11/2021
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
1/5/21: Suspension rope tails shall be shortened and clamped according to1996-103.4
|
8/11/2021
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
|
1/5/21: F(2) Bottom limit switch shall work. REINSPECTION REQUIRED
|
8/11/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Replace/repair Machine room smoke/heat detectors (3)
|
5/9/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
2-way communication device shall work and give proper location (REINSPECTION 15days)
|
5/2/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
1.18/8.6.4.13.1(l): Car Door restrictor shall work. Front and rear
|
5/2/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self-closing and self-locking. Door Jams, Knob not self-locking.
|
5/9/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
H(5) Machine room lighting needs to be repaired and guarded.
|
5/9/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil loss log and Fire service testing log, recorded monthly
|
5/9/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(2)(C) Re-Inspection Required to Enforce.
|
x
|
|
TESTING INCOMPLETE. MUST RETURN TO COMPLETE.
|
5/2/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(2)(C) Re-Inspection Required to Enforce.
|
x
|
|
TESTING INCOMPLETE. MUST RETURN TO COMPLETE
|
5/2/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
2-way communication device shall work and give proper location (REINSPECTION 15days)
|
5/2/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(2)(C) Re-Inspection Required to Enforce.
|
x
|
|
5.6/1001.2(e)(7) Governor Rope and/or Tail sheave shall be shortened/replaced/adjusted to allow proper Tension device clearance. Rope is beginning to rub linkage on bottom of car
|
5/9/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
VIO1: 1.18/8.6.4.13.1(l): Car Door restrictor shall work. Front (REINSPECTION REQUIRED) **2021 violation was repaired, restrictor later failed again 2022.***
|
3/8/2023
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
4th floor interlock cover to be reinstalled properly
|
3/8/2023
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
H(2) / 101.3d(1)(b) Machine room door shall be self-closing and self-locking. Door Jams,
|
3/8/2023
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)3
|
|
|
Escape hatch shall be secured
|
3/8/2023
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Roof drain piping union is leaking water onto machine room floor.
|
3/8/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
EMERGENCY LIGHTING SHALL WORK (only 1 bulb working)
|
3/8/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Phone not working on battery power
|
3/8/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. (Provided by Elev Co)
|
3/8/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
Provide current MCP in machine room
|
2/5/2024
|