Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 2.26.4.1 Yes No Relocate the main disconnect to provide the NEC required 3'6" clearance in front of the disconnect from the floor to the structure fix date 4/30/24above. 4/16/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Repair the pit light it is burnt out 10/15/2019
MO Minimum : Elevators (I) - Pits (I)1 No No Remove the standing water and oil from the pit floor, 7/19/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Replace the worn door gibb. 7/19/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Clean the dirty car top. 7/19/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Re fire seal around the doors at each level inside the hoistway 7/19/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit No No Clean up the mess in the pit. 9/21/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) No No Emergency light and bell not working 9/5/2018
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Repair the emergency alarm bell as it will not ring 11/15/2019