Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(p) x 1/5/21: Machine very noisy. Determine cause and repair/replace needed parts. REINSPECTION REQUIRED 8/11/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(p) x Machine very noisy. Determine cause and repair/replace needed parts. REINSPECTION REQUIRED 8/11/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x VIO1. B(11)/1.6.1/ : 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG 3/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x VIO3. G(1)1.18.1/8.6.4.13.1(l): Car Door restrictor shall work. (Front) 3/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars VIO4. G(1) Car-top light not working, clean cartop,clean pit 5/3/2022
MO Minimum : Elevators (I) - Pits (I)5 VIO5. I(5). : Pit Ladder shall be installed , accessible from each Pit access opening for each elevator. (#217 has a ladder but not accessible from #218 pit) 5/3/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x VIO6. G(1). Replace non-functional lamp in Emergency Light fixture (1 of 2 lamps not working) 3/31/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x VIO2. TESTING INCOMPLETE. Fire Service and Door# be tested to complete. F.S. Keys needed 3/31/2022
MO Minimum : Elevators (I) - Pits (I)1 Clean pit 5/3/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x VIO1. B(11)/1.6.1/ : 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG 3/31/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x VIO3. G(1)1.18.1/8.6.4.13.1(l): Car Door restrictor shall work. (Front) 3/31/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x VIO2. TESTING INCOMPLETE. Fire Service and Door# be tested to complete. F.S. Keys needed 3/31/2022
MO Minimum : Elevators (I) - Pits (I)5 Provide pit ladder #217 has one but not accessible from #218
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP in machine room 5/3/2024
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Car hoist ropes undersized, replace per code 8/5/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 2.17 machine noisey--determine cause & repair or replace parts 1/30/2020