ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.6.4.7 Cleaning of Pits
|
No
|
No
|
Clean up the oil and water from the pit floor.
|
7/19/2023
|
|
A17.1-2016 : Elevators
|
10.15 - Response to smoke detectors
|
8.6.8.15.17
|
Yes
|
No
|
Move the existing smoke detector in the hoistway up to within 12 inches of the hoistway ceiling.
|
5/22/2026
|
|
A17.1-2016 : Elevators
|
10.15 - Response to smoke detectors
|
8.6.8.15.17
|
Yes
|
No
|
Add an additional smoke detector in the recently enclosed area in front of the elevator creating a foyer at the lowest level of the elevator entrances.
|
5/22/2026
|
|
A17.1-2016 : Elevators
|
1.15 - sign and operating device symbols
|
2.26.12
|
Yes
|
No
|
Replace the missing braille plates at all the floors where they are missing.
|
5/22/2026
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
No
|
No
|
Remove the standing water from the pit.
|
5/7/2026
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
No
|
No
|
Replace the burnt out lights in the machine room
|
9/22/2021
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
No
|
No
|
Clean up the car top
|
9/21/2021
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.7 Cleaning of Hoistway and Pit
|
No
|
No
|
Clean up the mess in the pit
|
9/21/2021
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.7 Cleaning of Hoistway and Pit
|
No
|
No
|
Clean up the very dirty pit
|
7/25/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
No
|
No
|
clean the dirty car top
|
7/25/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.5.1 Examination and Maintenance
|
No
|
No
|
Repack the leaking jack seal
|
7/25/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
Yes
|
No
|
Replace the emergency light battery
|
6/15/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
No
|
No
|
Cut off the all thread above the new car ceiling on the car top
|
7/19/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
No
|
No
|
Clean the dirty car top.
|
7/19/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
No
|
No
|
Replace the badly rusted and oxidized door sill angle and the door, door frame, sill , sill support, at the lower level and the sill , sill angle, and facia between LL and !
|
9/22/2021
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
No
|
No
|
Emergency light and bell not working
|
9/18/2018
|