MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.5.16.5 Over Speed Valve Testing
|
|
|
Perform the required Cat 5 testing on the Overspeed Valve
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.36 - Hydraulic Cylinders
|
8.6.5.5.1 Examination and Maintenance of Packing Glands and Seals
|
x
|
|
Repair the hydraulic oil leak.
|
1/6/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.3 - Top-of-car operating device
|
8.11.2.1.3(c)
|
|
|
The car top inspection station does not operate as designed and would not operate properly. The device shall be repaired or replaced to operate as designed.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.8 - Door closing force
|
8.11.2.1.1(h)
|
x
|
|
The front and rear door closing force exceeds the 30 lbs. limit.
|
1/6/2021
|