Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 6/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No Replace the missing cover on the traveling cable junction box under the car. 6/7/2023
MO Minimum : Elevators (I) - Pits (I)1 No No The pit shall be kept clean and dry. 6/7/2023
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The pit light shall be operational. 6/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No Replace the missing cover on the traveling cable junction box under the car. 6/7/2023
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The pit light shall be operational. 6/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 6/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2 On-Site Documentation No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 3/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) Yes Yes Emergnecy light does not work. 5/15/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No A sill guard shall be installed. 1/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No A working emergency light shall be provided. 1/18/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No A working alarm bell with a 4 hour battery back-up shall be provided. 1/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Shall have working emergency light and alarm with 4 hour battery back up. (2nd Notice) 6/7/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No When car top inspection station is activated, control of the elevator shall only be operable from the car top inspection station. Currently the car controls are operational while on car top inspection. Take corrective action. 6/27/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No Top of car stop switch shall be operational. 3/31/2025
MO Minimum : Elevators (A) - Hoistways (A)3 Yes No 2nd and 3rd floor hoistway doors shall be self-closing. Take corrective action as needed. 3/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No A working emergency light shall be provided. 1/25/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes Yes A working alarm bell with a 4 hour battery back-up shall be provided. 1/25/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) Yes Yes Hoistway door locks shall not allow the elevator to run with the door open. 1/25/2022
MO Minimum : Elevators (F) - Electrical Switches (F)2 Yes Yes Final limits shall not allow the elevator to run when the switch is open. 1/25/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No A sill guard shall be installed. 1/25/2022