Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of current state operating certificate must be properly displayed
A17.1-2016 : Elevators 3.2 - Car top light and outlet 2.14.7.1.4 Cartop lighting missing both bulbs.
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 Pit has plastic oil line running from right cylinder head directly to tank, preventing measurement of oil leakage. Extend line and run into existing 5 gallon bucket in pit.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate.
A17.1-2016 : Elevators 3.2 - Car top light and outlet 2.14.7.1.4 One bulb still missing from car top, provide.
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 Return line is going back to the tank, remove. Place line into can in pit. If hose too short or damaged, replace.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x REPAIR PHONE IN THE CAR
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate POST CURRENT STATE CERTIFICATE IN THE MACHINE ROOM
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters Emergency Operation: Monthly Testing PERFORM MONTHLY FIRE SERVICE TEST AND DOCUMENT ON THE LOG POSTED IN THE MACHINE SPACE
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 x OSV is due for testing, provide. 5/21/2025