ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not work.
|
12/11/2019
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Flexible conduit in hoistway needs to be fastened to hoistway ceiling
|
5/14/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.20 - Governor rope
|
2.18.5
|
x
|
|
It appears the governor rope needs to be shortened as the governor tail sheave is at or nearing its full travel.
|
8/12/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.3 - Lighting and receptacles
|
2.7.5.1
|
|
|
Lighting in hoistway overhead machine space shall work
|
5/14/2024
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Need to clean pit
|
5/14/2024
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Phase 1 and Pase 2 fire service did ot operate correctly
|
8/20/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
2.4.2
|
x
|
|
Provide code compliant runby.
|
8/12/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2 Design and Construction of Pits
|
|
|
The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor.
|
8/26/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2 Design and Construction of Pits
|
|
|
The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor.
|
8/26/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2 Design and Construction of Pits
|
|
|
The elevator pit shall be cleaned of dust and debris.
|
8/26/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.2 - Hoistway doors
|
8.11.2.1.4(b)
|
x
|
|
The hoistway door tension on the lower landing shall be repaired to self-close.
|
8/4/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.3 - Lighting and receptacles
|
8.11.2.1.2(c)
|
|
|
The machine space lighting was not operational on the day of inspection. Repair lighting for proper illumination for maintenance and emergency personnel.
|
8/26/2022
|