MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)10 Car Floors
|
|
|
Lobby floors (both) have broken tiles prior to entry to elevator, this is a tripping hazard. Repair as needed.
|
4/22/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
Provide existing door open button to work ( hitting floor number opens door).
|
4/22/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.17 - Standby power operation
|
3.26.10 (Auxiliary Power)(Re-Inspection)
|
x
|
|
Battery backup lowering unit is not working properly.
|
4/29/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.5.16.5 Over Speed Valve (Red Tag)
|
x
|
x
|
OSV is leaking hydraulic fluid, repair OSV, test with full load and check tripping speed. Red tagged, Re-inspection required
|
2/14/2024
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5 Over Speed Valve (Red Tag)
|
x
|
x
|
OSV was tested, passed. However, it is still leaking excessively, RED TAG remains.Repair and retest.
|
4/29/2024
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5 Over Speed Valve (Red Tag)
|
x
|
x
|
Overspeed valve is not setting. Overspeed shall function so in case of a pipe burst the car will not free fall into pit. RED TAG
|
4/29/2024
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.4.19.6
|
x
|
|
Phase I fire service does not work, needs repair. Re-inspection required
|
2/14/2024
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current State Elevator Certificate.
|
4/22/2024
|