Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars clean car top 1/9/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit lights are burnt out 1/9/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 2.20 1/5/21: 2.20.9.5.4 : Hoist rope retaining clip missing, car side. 4/16/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 1/5/21: 2-way communication device shall work and give proper location (REINSPECTION REQUIRED) 8/11/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(p) x 1/5/21 Machine bearings or worm/ring need to be repaired/replaced. VERY noisy. 8/11/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 1/5/21: 2-way communication device shall work and give proper location (REINSPECTION REQUIRED) 8/11/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(p) x 1/5/21 Machine bearings or worm/ring need to be repaired/replaced. VERY noisy. 8/11/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x TESTING INCOMPLETE. MUST RETURN TO COMPLETE. 3/30/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 8.11.2.1.3(cc)(1) Wire ropes shall be replaced x x UNDERSIZED/DAMAGED ROPES. 3/30/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x TESTING INCOMPLETE. MUST RETURN TO COMPLETE. 3/30/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 8.11.2.1.3(cc)(1) Wire ropes shall be replaced x x UNDERSIZED/DAMAGED ROPES. 3/30/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 2-way communication device shall work and give proper location 3/31/2022
MO Minimum : Elevators (H) - Machine Rooms (H)7 Replace/repair broken flex connector on governor wiring. 5/1/2022
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove trash/old parts from machine room. Clean as needed. 5/1/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Replace non-functional controller cooling fans and keep controller doors closed and latched. 5/1/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates x Phase 1 Indicator LED @ 1st Floor not working. 11/18/2022
MO Minimum : Elevators (I) - Pits (I)1 Clean Pit. 11/29/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP in machine room 2/5/2024