A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2 On-Site Documentation
|
x
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
10/24/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Check all phases of fire service and all initiating devices when the 2nd modernization is completed. (Phase 1 & 2 fire service, smoke detectors, and heat detectors have been checked for this car)
|
10/24/2022
|
A17.1-2016 : Elevators
|
4.5 - Access to Hoistway
|
8.10.2.2.4(e)
|
x
|
|
Check hoistway access once installed.
|
10/24/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Emergency stop not over-ridden during Phase I recall
|
6/17/2021
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)5
|
|
|
Gate switch exceeds the maximum of 2 inches. Reinspect.
|
6/18/2019
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
x
|
Hoist ropes shall be shortened so that the car has a minimum of 6" of runby and can reach the final limit. This unit has been Red-tagged. Re-inspection required
|
12/14/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Install all hall fixtures.
|
10/24/2022
|
A17.1-2016 : Elevators
|
1.15 - sign and operating device symbols
|
8.10.2.2.1(o)
|
x
|
|
Install all the required signage in the cab.
|
10/24/2022
|
A17.1-2016 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
8.10.2.2.2(m)
|
x
|
|
Install electrical covers on all devices missing covers in the machine room.
|
10/24/2022
|