Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) Yes No This elevator has an OSV device installed that is not sealed and is required to have 5 yr full load test. Re-inspection required 9/25/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 8.11.2.3.5 Yes No Emergency return unit, battery lowering, inoperative. Repair. 8.6.1.6.3(e) 4/3/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Provide maintenance control program on site documents. 10/20/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting Yes No The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. Reinspection required. 4/25/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.11 - Plunger and Cylinder 3.18 No No The hydraulic cylinder gland packings are leaking excessively on both cylinders and shall be replaced. 2/25/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) Yes No OSV is not sealed and needs to have a 5 yr full load test performed. Re-inspection required 5/29/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Yes No Emergency return unit (ERU) is inoperable. The ERU batteries shall be replaced in order for the ERU to conform to the ERU requirements. 9/17/2024