Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.3 Guards Between Adjacent Pits 2.2.2.6 sumps in pits shall be covered, it is leaning against the wall without the needed cutouts to be installed over the sump hole 1/1/2021
A17.2-2014 : Elevators 1.18 - Restricted opening of car or hoistway doors 1.18.1(a) car door restrictor missing parts and needs repaired 4/30/2019
conversion conversion n/a do not store non-elevator relaed equipment in the machine room 8/17/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Rooms and Machinery Spaces Do not store non-elevator related items in the machine room
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Rooms and Machinery Spaces Do not store non-elevator related items in the machine room (8.6.4.8.2) 6/25/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x emergency phone did not work, the phone line has dial tone but it would not dial out 10/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone was not answered
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 need to fill out the monthly fire service test log in the machine room every month 1/1/2021
A17.1-2016 : Elevators 2.5 - Housekeeping 8.11.3.1.2(h) non elevator related material is not to be stored in the elevator machine room 12/1/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Perform monthly fire service test and post log in the machine room. 1/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post a current copy of the state operating certificate in the Elevator machine room. The one that’s on display is several years old.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate post cop of the state operating certificate in the machine room 1/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.8 remove large peice of PVC pipe laying on the pit floor that is not hooked to anything 1/1/2021
conversion conversion n/a repair door restrictor 8/17/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x Repair the door restrictor, it is missing parts 10/12/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(2) The firefighters service test log is not being filled out monthly. 12/1/2022
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room is from 2017, a new copy is to be displayed every year 12/1/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.11.3.1.5(a) the sump pump is plugged in the GFCI outlet, it should be plugged into the single outlet that was provided for the sump pump 12/1/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Water and pit, hydraulic line completely submerged in water, sump pump is not even plugged in, maintain dry pit. Repeat from 2022 (2.2.2.3) 6/25/2024
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.3 water in pit, hydraulic line completely submerged in water, sump pump is not even plugged in, permanent provisions shall be made to prevent accumulation of ground water in the pit 7/10/2023
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.11.3.1.5(a) water in the oil collection pan 12/1/2022