Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 2.14.7.1.1 Not less than two lamps elevator cab only has one working ceiling light bulb, required to have minimum working light bulbs, replace burnt out bulbs 7/10/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 monthly fire service test log in the machine room is not being filled out monthly 1/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Perform monthly fire service test and post log in the Machine Room. 1/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate post copy of the state operating certificate in the machine room 1/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x repair door restrictor it is missing parts 11/13/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x Repair the car door restrictor, it does not work, parts missing 10/12/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the elevator machine room expired in 2018, update with a copy of the current certificate annually 7/10/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The state operating certificate in the machine room expired in 2018, update with the new certificate annually 6/25/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The state operating certificate in the machine room expired in 2022, update with the new certificate annually
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room is from 2017, a new copy is to be displayed every year 12/1/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.2-2.27.8 x x the stop switch in the fire service panel blows a fuse when activated 10/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.4 - Hoistway door locking devices 2.12 x Top landing hoistway Unlocking device is off and lying on the car top 11/19/2024