Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x x Emergency phone line does not operate. Phone shall establish two way communication and be monitored by a 24 hour service. Elevator is not equipped with a bell. RED TAG 3/13/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Annual inspection was not completed. Still have to inspect hoistway, fire service, and relief pressure 3/13/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 2.14.7.1.3 Provide Auxiliary Lighting x Repair inoperative emergency light 3/13/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1.1.1 Means of Communication (Red Tag) x x Provide active phone line for the emergency phone. Red tagged, Re-inspection required 4/25/2023
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 2.14.7 x x Repair inoperative emergency light. Red tagged, Re-inspection required 4/25/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.3 - Lighting and receptacles 2.7.5.1 Lighting Provide 19 ft candles of illumination measured at the floor in front of the controller
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.3 - Lighting and receptacles 2.7.5.1 Lighting Provide 19 foot candles of illumination measured at the floor in front of the controller
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate.