Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x In car "Help button" pushed in, repair and test phone. 9/30/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11 Periodic Inspection and Test. x TESTING INCOMPLETE due to Maint Co. scheduling conflicts and issues. REMAINING: all weight tests, buffer tests, slide, 9/30/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11 Periodic Inspection and Test. x There are no 5 yr test tags on elevator equipment. Re-inspection required 8/15/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.3 - Top-of-car operating device 8.11.2.1.3(c) x Car top inspection station does not work, needs repair. Re-inspection required Rule 2.26. 1.4.1 (A) 11/15/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 8.11.2.1.3(cc)(1) Wire ropes shall be replaced x x Elevator has broken suspension cable, replace all cables. Red tagged, Re-inspection required Rule 8.6.3.2 11/15/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current State Operating Permit, expired 4/11/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Not Present: MCP, Testing procedures, Fire service log, 4/11/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.5 - Access to Hoistway 8.6.4.14 Hoistway Access Switches Hoistway access switch at top landing non-functional, Repair. 4/11/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 8.11.2.1.3(cc) [1001.2(c)(29)]//8.6.1.6.2 : Hoist Ropes appear dry and showing “rouge”. Ropes shall be cleaned and lubricated per OEM recommendations. ( ) 4/11/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits I(1) : Excessive debris in pit (combustible hazard) 4/11/2023
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 There are no 5 year test tags on elevator equipment. Have elevator company performed 5 year test to tag equipment 4/11/2023
A17.1-2016 : Elevators 3.3 - Top-of-car operating device 8.11.2.1.3(c) Car top inspection does not work 4/11/2023