Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.43 - Emergency Brake, Ascending Car Overspeed, and Unintended Car Movement Protection 8.6.4.20.11 (Re-Inspection) x G(1). EBR (Emergency Brake Release) unplugged. Shall be repaired/replaced, (REINSPECTION REQUIRED) 8/10/2022
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Provide current state operating certificate 8/14/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.17 - Drive machine brake 2.24.8.3 x 2.24.8.4 EBR module batteries failed. Repair/replace Emergency Brake Release Module. (30day reinspection) 12/23/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.17 - Drive machine brake 2.24.8.3 x 2.24.8.4 EBR module batteries failed. Repair/replace Emergency Brake Release Module. (30day reinspection) 12/23/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.17 - Drive machine brake 2.24.8.4 Means for Manual Release x 2.17/2.24.8.4 EBR module batteries failed. Repair/replace Emergency Brake Release Module. (REINSPECTION REQUIRED) 2/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1.1.5 Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x B(11)/1.6.1/ : 2-way communication device shall work(with and w/o main power) and give proper location (REINSPECTION 14days to REDTAG) 2/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 G/2.7.1/8.6.1.6.5: Machine Room shall have proper Fire Extinguisher (5-10lbs, ABC) and shall have current monthly/annual test tag. 10/15/2022