A17.1-2016 : Elevators
|
5.11 - Plunger and Cylinder
|
8.6.5.5
|
|
|
8.6.5.5.2 - Oil leakage collected from each cylinder head seal or packing gland shall not exceed 5 gallons before removal. (The oil recovery line from the hydraulic head is presently being run directly to the tank - oil loss cannot be monitored)
|
10/15/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
8.11.3.1.5 (j) Car Safety
|
|
|
A category 5 test shall be performed.
|
6/29/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
10/15/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.34 - Flexible Hydraulic Hose and Fitting Assemblies
|
3.19.3.3 Flexible Hydraulic Connections
|
x
|
x
|
A hydraulic hose in the pump unit ruptured. Elevator Red Tagged.
|
11/3/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
All annual inspection items still need to be witnessed with the exception of the hoistway scan.
|
11/3/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Display a copy of the current state operating certificate in the machine room.
|
12/17/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Provide code compliant maintenance records.
|
12/24/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.31 - Slack Rope Device - Roped-Hydraulic Elevators Installed Under A17.1b-1989 and Later Editions
|
8.11.3.1.3(z)
|
|
x
|
Slack cable switch not operating. Unit Red-Tagged.
|
2/15/2019
|
A17.1-2016 : Elevators
|
2.13 - Governor, Overspeed Switch, and Seal
|
8.11.3.1.2(bb)
|
|
|
The governor shall have a test tag installed.
|
6/29/2020
|