Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)4 REMOVE ALL NON-ELEVATOR RELATED ITEMS FROM MACHINE ROOM 8/8/2024
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter phase 1 instructions next to hall fire keyswitch. Presently has phase 2 instructions next to hall fire service keyswitch. 6/13/2023
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter phase 1 instructions next to hall firefighter keyswitch, not phase 2 instructions. 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No MCP 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No MRL on site 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Machine room fire extinguisher certification has expired. 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post In Case of Fire signage next to hall button fixture at each landing 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder drain lines run back to pumping unit. Cylinder drain lines need to be ran into pit collection containers. Each cylinder shall have a seperate collection container of no more than 5 gallon capacity. 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Cylinder drain lines run to hydraulic tank. Remove from tank and run to pit containers of no more than 5 gallons. 6/13/2023
conversion conversion n/a Provide fire service instructions inside and outside elevator. 6/13/2023
conversion conversion n/a elevator phone does not function. 6/13/2023