Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Provide fire service instructions inside and outside elevator. 2/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Remove scavenger pump from pit. Cylinder drain line needs to be ran to pit container of no more than 5 gallons. 2/22/2023
MO Minimum : Elevators (I) - Pits (I)1 No No Remove standing water from pit. Pits shall be kept dry and clean. 2/22/2023
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Firefighter phase 2 operation does not overide security for bottom floor car call. 14 days to correct or elevator will be red tagged. 8/23/2021
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log No No Test and log firefighter operation monthly 9/8/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Remove scavenger pump from pit 9/8/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance No No Replace plunger packing. Packing leaks excessively 9/8/2021
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Firefighter instructions inside the elevator need to be for phase 2 operation not phase 1 9/8/2021
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Firefighter instructions next to hall fire keyswitch need to be for phase 1 operation not phase 2 9/8/2021
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Firefighter phase 2 operation does not override security for bottom floor car call. 14 days to repair or red tagged. May apply for variance from the state 9/8/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Remove scavenger pump from pit 2/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance No No Replace plunger seal. Seal leaks excessively 2/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Machine room fire extinguisher certification is expired. 2/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No No MCP 2/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No MRL not up to date 2/22/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State operating certificate not displayed 2/22/2023
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No PROVIDE PHASE 2 FIRE SERVICE SIGNAGE 8/8/2024