Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation Perform monthly fire service test & document on log wit the maintenance control plan 11/20/2020
A17.1-2016 : Elevators 7.19 - Maintenance records 8.6.1.2.1(e) Need a maintenance control program on site posted in machine room 8/4/2021
A17.1-2016 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Room and Machinery Space Provide secure storage outside the hoistway for prints,mcp logs, etc, 8/6/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Mount Fire extinguisher on hoistway wall and serviced & tagged accordingly (Machine room less) 11/20/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Provide maintenance control; program & provide storage outside the hoistway 11/20/2020
A17.1-2016 : Elevators 1.12 - Car enclosure 8.10.2.3.2(s) Belt monitor was written out of operating system: Red Tagged 8/4/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) Insure maintenance records-prints-ECT. To be located outside the hoistway & car top 9/19/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation Place monthly fire service test log in machine room 9/12/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements x Repair Seismic operation 10/14/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Perform 5 year full load test 8/22/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair alarm bell in the car 7/29/2021
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Make car bell operational 8/5/2021