Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Yes No Emergency rescue unit does not work, battery has no power, Re-inspection required 10/3/2024
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Yes No Overhead machine space lighting does not work and is not mounted properly, needs repaired. Re-inspection required 10/3/2024
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Yes No Overhead machine space lighting does not work and is not mounted properly, needs repaired. Re-inspection required 4/15/2025
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Yes No Top of hoistway lights are not working, repair as needed.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Existing battery back up system does not work. 6/15/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting Yes No Repair inoperative emergency light 4/24/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Reprogram the emergency phone to call a monitored station 4/24/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.17 - Drive machine brake 8.11.2.3.4 Yes No Brake does not hold 125% capacity. Re-inspection required 7/20/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Provide on site maintenance records and monthly elevator fire log. 6/29/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.11.2.1.2(g) No No Provide up to date test tag on fire extinguisher. 6/29/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 No No Provide fire extinguisher and test it annually. 6/29/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Door Systems Yes No All hoistway doors are missing bottom door fire tabs, provide.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current State Elevator Certificate.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display current operating certificate. 6/29/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current operating certificate. 6/29/2021