MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
x
|
Phone, emergency bell and emergency light failed to operate. Elevator was red tagged power shut off at disconnect. Email sent to office.
|
12/19/2022
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency alarm shall work.
|
3/20/2019
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1001.2(b)(5)
|
|
|
Only items relating to the operation of the elevator shall be stored in the machine room. All non-elevator related materials shall be removed from the machine room.
|
5/13/2019
|
A17.1-1996 : Elevators
|
2.7 - Fire Extinguisher
|
1001.2(b)(7)
|
|
|
A ABC type fire extinguisher shall be provided in the machine room.
|
5/13/2019
|
A17.1-1996 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
1001.2(c)(18)
|
|
|
All hoistway wiring shall be enclosed in conduit.
|
5/13/2019
|
A17.1-1996 : Elevators
|
3.14 - Hoistway clearances
|
1001.2(c)(20)
|
x
|
|
Complete fascia is required to maintain proper car clearances.
|
7/9/2019
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1001.2(d)(12) -
|
|
|
"Do not use in case of fire" signage is required.
|
5/13/2019
|
A17.1-1996 : Elevators
|
4.2 - Hoistway doors
|
1001.2(d)(2)
|
|
|
The distance between the inside face of the hoistway door and the edge of the landing sill shall be less than 3".
|
5/13/2019
|
A17.1-1996 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
1001.2(e)10
|
x
|
|
A Category 5 full load test shall be witnessed.
|
3/20/2019
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
A pit light switch is required.
|
5/13/2019
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7
|
|
|
Emergency lighting shall work.
|
5/13/2019
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7
|
|
|
Emergency light shall work.
|
5/13/2019
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7a (3)(a) Standby Illumination in the car. (Re-Inspection)
|
x
|
|
Emergency light failed to operate during test.
|
3/1/2022
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A variance shall be requested to allow a residential elevator to be installed in a commercial application.
|
5/13/2019
|