Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x G(1)/8.6.4.15/1.5.1(b) : Emergency/auxiliary lighting shall work with power loss. (REINSPECTION REQUIRED) 1/19/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x G(1)/8.6.4.15/1.5.1(b) : Emergency/auxiliary lighting shall work with power loss. (REINSPECTION REQUIRED) 1/19/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers G/2.7.1/8.6.1.6.5: Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired) 1/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods MCP shall be kept in equipment room, including Oil loss log and Fire service testing log, recorded monthly. 1/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Repair rear handrail inside cab 1/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection G/8.6.5.5.2 Pit scavenger pump will be removed or routed to a measurable container. 1/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit clean cartop and pit, excessive debris 1/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Replace missing hall fire signage “ in case of fire…..” 3/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records G(1)/A17.1-2016:8.6.1.6 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) 3/15/2022
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self-closing and self-locking. Push button locking not allowed, and closer does not fully close door. 3/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates 11 CSR 40-5.070 : ADA Requirements: buttons missing Braille Identification. 3/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Repair COP side reveal panel (damaged, exposing bulbs and wiring) 3/15/2022
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) H(5) Machine room lighting needs to be guarded 3/15/2022
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room light must be guarded 6/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide mcp in machine room 6/22/2023
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine lighting must be protected 12/4/2023