ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.7 - Fire Extinguisher
|
8.11.2.1.2(g)
|
|
|
Provide a current tested fire extinguisher in the elevator machine room.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.11 - Disconnecting Means and Control
|
2.26.4
|
|
|
Provide feeder location on main line and 110v disconnect.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Display a copy of the current state operating certificate.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.15 - sign and operating device symbols
|
8.11.2.1.1(o)
|
|
|
Post elevator lobby warning placards on all floors.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.9 - Floor and emergency identification numbering
|
8.11.2.1.3(o)
|
|
|
Provide elevator numbering inside hoistway at all doors.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Provide a completed maintenance control program (MCP) on site.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO state operating certificate shall be displayed in the elevator machine room.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Provide a code compliant MCP including onsite documents.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.7 - Fire Extinguisher
|
8.6.1.6.5
|
|
|
A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.9 - Floor and emergency identification numbering
|
8.11.2.1.3(o)
|
|
|
Provide floor numbering on inside of hoistway doors.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.9 Elevator Corridor Call Station Pictograph
|
|
|
Provide "In case of fire" signage on all floors.
|
12/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.4 - Normal terminal stopping devices
|
8.11.2.2.5
|
x
|
|
The bottom limit switch shall be adjusted to stop the movement of the car prior to striking the buffer.
|
3/2/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.5 - Normal terminal stopping device
|
8.11.2.1.3(g)
|
x
|
|
The upper terminal device shall be adjusted to stop the movement of the car prior to contacting the directional limit switch.
|
3/2/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.9 - Floor and emergency identification numbering
|
8.11.2.1.3(o)
|
|
|
Hoistways shall have floor numbers, not less than 4 inches in height, on the hoistway side of the hoistway door.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.17 - Door and gate equipment
|
8.11.2.1.3(w)
|
|
|
Stops shall be provided to prevent hoistway door hangers from overrunning the track.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.9 - Power closing of doors or gates
|
8.11.2.1.1(i)
|
|
|
The door data plate shall be completed with the door speeds.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.4 - Sills and car floor
|
8.11.2.1.1(d)
|
|
|
There is missing carpet inside the car that creates an unlevel and unsafe surface.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.12 - Car enclosure
|
8.11.2.1.1(l)
|
|
|
The position indicator shall be securely attached to the car enclosure.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
The emergency two-way communication does not work when car 110v removed.
|
3/2/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
The emergency recording gives the wrong location.
|
3/2/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.4 - Normal terminal stopping devices
|
8.11.2.2.5
|
x
|
|
The bottom limit switch shall be adjusted to stop the movement of the car prior to striking the buffer.
|
4/25/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.5 - Normal terminal stopping device
|
8.11.2.1.3(g)
|
x
|
|
The upper terminal device shall be adjusted to stop the movement of the car prior to contacting the directional limit switch.
|
4/25/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the machine room, in a noncombustible frame with a clear protective vision plate over it.
|
|