Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(2) the monthly fire service test log is to be filled out monthly 5/3/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Repair the sump pump, water in the pit 5/3/2022
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the state operating certificate is to be posted in the controller room 5/3/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(2) monthly fire service test log is from 2021, could not find a 2022 log, fire service test is to be performed monthly and logged 10/5/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation maintenance control program (MCP) book was not in the controller room 10/5/2022