MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
No guard on car light fixture
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)4
|
|
|
To much space between inside hoist way door and car gate
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
No "maintenance control program" records
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door not self closing or locking
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Gutter / shield pipes in machine room to protect controller
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
No pit light
|
|
conversion
|
conversion
|
n/a
|
|
|
Gutter water pipes that run over controller
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Escape hatch needs to be bolted down from car top
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Pit needs permanent light fixture switch shall be accesible from pit access door
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Cover needed for interlock at Floor L
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Pit needs ladder, it shall extend 30in above the sill or provided hand grip
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Floor B and Floor 1 needs about 1 1/2 in spacer on hoistway door to meet allowable space requirements
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Pit full of oil needs to be removed
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Pit stop switch shall provided IAW A17.1 1995 It shall be accessible from pit access door
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
Need 5 Gal pit bucket in pit to collect oil from overflow from head
|
3/23/2021
|
conversion
|
conversion
|
n/a
|
|
|
If hydraulic cylinder not replaced the packing for cylinder head needs to be replaced.
|
3/23/2021
|