A17.1-2016 : Elevators
|
2.18 - Traction drive machines
|
2.24.2.3 Traction
|
x
|
|
Elevator will not pick car with full load, needs repaired. Red tagged, removed from service. Re-inspection required
|
5/23/2023
|
A17.1-2016 : Elevators
|
2.18 - Traction drive machines
|
2.24.2.3 Traction
|
x
|
x
|
Elevator will not run with capacity load. Red tag remains.
|
8/29/2023
|
A17.1-2016 : Elevators
|
2.29 - Car and counterweight safeties
|
8.6.4.20.1
|
x
|
x
|
Test car safeties with rated load at rated speed. Red tagged, Re-inspection required
|
5/23/2023
|
A17.1-2016 : Elevators
|
2.29 - Car and counterweight safeties
|
8.6.4.20.1
|
x
|
x
|
Test car safeties with rated load, at contract speed.
|
8/29/2023
|
A17.1-2016 : Elevators
|
2.13 - Governor, Overspeed Switch, and Seal
|
8.6.4.20.2
|
x
|
|
Check car governor tripping speed, record.
|
8/29/2023
|
A17.1-2016 : Elevators
|
2.13 - Governor, Overspeed Switch, and Seal
|
8.6.4.20.2
|
x
|
x
|
Governor rope pull through force is excessive (1000 lbs) governor data plate maximum pull through force is 180 lbs. Repair governor to get correct pull through force. Red tagged, Removed from service. Re-inspection required
|
5/23/2023
|
A17.1-2016 : Elevators
|
2.13 - Governor, Overspeed Switch, and Seal
|
8.6.4.20.2
|
x
|
|
Check car governor tripping speeds. Re-inspection required
|
5/23/2023
|