Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Install spaceguards on hoistway swing doors. Distance from landing sill to face of hoistway door exceeds 3 inches. 5.3.1.7.2
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post "500 LBS Capacity" plate inside the elevator. 5.3.1.20.1
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Provide on site documentation of procedures performed according to the maintenance control plan.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide type ABC fire extinguisher inside machine room..
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide written maintenance control plan in place that specifies examinations, tests, cleaning, and lubrication