Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 3.23 - Suspension Means 8.11.2.1.3(cc) x the coated steel belt monitor is flashing an error, fix the belt monitor and/or replace as needed 11/17/2022
A17.1-2016 : Elevators 3.23 - Suspension Means 8.11.2.1.3(cc) x the coated steel belt monitor is flashing an error on one of the belts, verify that the hoistway belt is good and reset the monitor, if the belts test bad then replace the hoist belts (2.24.9.3) 11/1/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate on display in the elevator machine room is to be updated annually when received from the state
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters Emergency Operation: Monthly Testing Perform monthly fire service test and have the log available to the inspector 8/31/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) the on site documentation is being stored on the car top, the AHJ wants it to be stored in a location outside of the hoistway and readily accessible to elevator personnel
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the operating certificate should be displayed in the same location as the on site documentation