Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Complete annual CAT 1 test 11/12/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.13 - Governor,overspeed switch and seal 2.17.15 x Repair governor tail sheave switch 11/12/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Remove water from pit 11/1/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.3 - Lighting and receptacles 2.7.5.1 Lighting Repair machine space hoistway-top lighting
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone shall work. 2/19/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 8.11.2.1.3(cc)(1) Wire ropes shall be replaced x x reinspectin for rouge on hoisting belts, no engineer letter supplied to me, 15 days to either receive letter from engineer stating belts are ok or the belts to be replaced or a rd tag unit place out of service. 1/15/2024
A17.1-2016 : Elevators 3.6 - Final and emergency terminal stopping devices 8.11.2.1.3(h) x x Repair bottom final limits switch operations 2.25.3.2 11/21/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.20 - Governor rope 8.11.2.1.3(z) x Shorten Governor rope 2.18.6.4 11/21/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.11.2.1.5(a) Channel pit floor to sump pump in drain standing water. 2.2.2.3 1/5/2023
A17.1-2016 : Elevators 5.6 - Governor-rope tension devices 8.11.2.1.5(g) Replace rusting conduit to governor tail sheave switch 620.21 1/5/2023
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.11.3.1.5(a) Channel Pit Floor to sump pump to drain Standing water in pit 2.2.2.3 1/5/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Need maintenance control program on site posted on controller on or by next test 12/21/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Need testing procedures in the MCP on or before 1/1/22 12/20/2021
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log x Tested fire service failed
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) x Hoisting belts have red rouge all over needs to be replaced 10/19/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits Pit shall be kept clean and dry. 3/25/2019