Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x door restrictor did not work, hook has been removed 1/23/2024
A17.1-2016 : Elevators 1.4 - Sills and car floor 8.11.3.1.1(d) new cab floor covering is not as thick as the old covering, there is now a trip hazard because of the height difference between the cab floor and the car sill 12/2/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4 Instructions for Locating Maintenance Records the maintenance control program booklet from Schindler is not in the machine room 12/9/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Perform monthly fire service test and post log in the Machine Room. 2/11/2020
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.11.3.1.5(a) oil on the pit floor needs to be cleaned 12/2/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits clean up oil on pit floor, clean up oil soaked rags in the pit