Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.15 - sign and operating device symbols 8.11.2.1.1(o) x In Case of Fire signage 1/10/2019
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.11.3.1.1(r) x repair the door restrictor, it is not working 11/30/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Speaker not working 1/10/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x phone not owrking 1/10/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.4 - Machine space 2.7.1.1 Repair hole in machine room ceiling Sheetrock 11/11/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.6 - Ventilation 8.11.2.1.2(f) Machine room air conditioner is dripping water onto the machine room floor, clean the drain line (2.8.5.3) 11/11/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.6 - Ventilation 8.11.2.1.2(f) Machine room air conditioner not working, repair air conditioner to maintain machine room to the temperature and humidity level per the data tag on the elevator equipment (2.7.9.2) 11/11/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits x penetrations need to be filled and pit cleaned 1/10/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.1.6(h) Phase 2 Audible/Visual Signal (Re-Inspection) x the fire service audible signal in the elevator did not work, repair audible signal 1/23/2024