Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) A written Maintenance Control Program shall be in place to maintain the equipment with the requirements of section 8.6
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 6.1.3.3.6 x 6.1.3.3.9 - Step indexing shall be tested. 7/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 6.1.6.7 Top & bottom demarcation lights don't work 4/4/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 6.1.6.7 Top and Bottom Demarcation Lights do not illuminate 4/4/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 6.1.6.3.13 x Comb plate impact switches are not functioning properly. One on top, one on bottom. 7/2/2018