Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.8 - Hoistway enclosure 8.11.2.1.4(h) No No Hoistway doors shall be numbered.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.13 - Emergency exit 8.11.2.1.1(m) No No Escape hatch does not work electrically.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.7 - Car door or gate 8.11.2.1.1(g) No No Car gate shall work electrically.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.2 - Hoistway doors 8.11.2.1.4(b) Yes No Side panel shall extend 30" from door on all floors. 11/23/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.2 - Hoistway doors 8.11.2.1.4(b) Yes No A10.4 - 11.4 - All newly installed landing gates shall be located within 8" or less from the edge of the building to the inside of the gate. Reinspection Required 6/5/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.4 - Hoistway door locking devices 8.11.2.1.4(d) Yes No Hoistway doors shall be guarded 30" on both sides to height of doors. 10/15/2018