ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.5 - Car lighting and receptacles
|
8.11.2.1.1(e) Car Lighting
|
|
|
The 110V car light disconnecting means in the electrical room at "*2" shall be capable of being locked in the open position
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.27 - Crosshead data plate
|
8.11.2.1.3(k)
|
|
|
The crosshead data plate shall be legible per
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
8.11.2.1.3(m)
|
|
|
Secure the counterweights in the counterweight frame
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
8.11.2.1.5(b)
|
x
|
x
|
The minimum car runby shall be 6 inches
|
|
conversion
|
conversion
|
n/a
|
|
|
The 110V car light disconnecting means in the electrical room at "*2" shall be capable of being locked in the open position
|
|
conversion
|
conversion
|
n/a
|
|
|
Elevator released for temporary use until 2-12-2018. Correct / Address all deficiencies and schedule an inspection by 2-12-2018
|
|
conversion
|
conversion
|
n/a
|
|
|
Sure-up electrical in the electrical room at "*2"
|
|
conversion
|
conversion
|
n/a
|
|
|
The crosshead data plate shall be legible
|
|
conversion
|
conversion
|
n/a
|
|
|
Secure the counterweights in the counterweight frame
|
|
conversion
|
conversion
|
n/a
|
|
|
The minimum car runby shall be 6 inches
|
|
conversion
|
conversion
|
n/a
|
|
|
Provide working Schindler's PEBO and test
|
|
conversion
|
conversion
|
n/a
|
|
|
Schindler's data plate in pit.
|
|