Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Elevator released for temporary use until 2-12-2018. Correct / Address all deficiencies and schedule an inspection by 2-12-2018
conversion conversion n/a Provide working Schindler's PEBO and test
conversion conversion n/a Schindler's data plate in pit.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.28 - Counterweight and counterweight buffer 8.11.2.1.3(m) Secure the counterweights in the counterweight frame
conversion conversion n/a Secure the counterweights in the counterweight frame
conversion conversion n/a Sure-up electrical in the electrical room at "*2"
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.11.2.1.1(e) Car Lighting The 110V car light disconnecting means in the electrical room at "*2" shall be capable of being locked in the open position
conversion conversion n/a The 110V car light disconnecting means in the electrical room at "*2" shall be capable of being locked in the open position
conversion conversion n/a The crosshead data plate shall be legible
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.27 - Crosshead data plate 8.11.2.1.3(k) The crosshead data plate shall be legible per
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.11.2.1.5(b) x x The minimum car runby shall be 6 inches
conversion conversion n/a The minimum car runby shall be 6 inches