Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.5 - Housekeeping 8.11.2.1.2(h) Closet next to elevators is a machine space. Remove all non elevator related equipment 12/7/2022
A17.1-2016 : Elevators 2.1 - Access to machine space 8.11.2.1.2(b) Machine space doors to be self closing 12/7/2022
A17.1-2016 : Elevators 2.1 - Access to machine space 8.11.2.1.2(b) Machine room door to be self locking 12/7/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Provide MCP 12/7/2022
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Expired 12/7/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Existing phone not working. Repair as needed 1/20/2022
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 8.11.2.1.2(p) Provide feeder location on main line disconnect. 12/7/2022
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 8.11.2.1.2(p) Provide feeder location on 110v. disconnect. 12/7/2022
A17.1-2016 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Room and Machinery Space Closet next to elevator is in machine space, remove non elevator equipment 12/7/2022
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room doors need to be self closing and self locking 12/7/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Provide MCP 12/7/2022
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Expired fire extinguisher 12/7/2022
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 2.26.4.1 Provide feeder location on main line disconnect 12/7/2022
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 2.26.4.1 Provide feeder location on 110 v disconnect 12/7/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) provide an on-site maintenance control program. 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 provide a current tested fire extinguisher in elevator control room. 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Fire extinguisher expired. In the main disconnect room on top floor 10/30/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 x Fire extinguisher is expired, have serviced or replaced. Re-inspection required 10/7/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Fire extinguisher is expired in the main disconnect room on top floor. Have serviced or replaced
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Rooms and Machinery Spaces remove all non elevator equipment from contol space 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.1 provide feeder location on main line disconnect 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.1 provide feeder location on car light disconnect 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 elevator control room door to be self locking. 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 elevator control room to be self closing. 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 8.11.2.1.2(a) Closet next to elevator is an elevator room, remove all non elevator related equipment from this space. 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 8.11.2.1.2(a) Elevator room doors are to be self closing and self locking 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.11 - Disconnecting Means and Control 8.11.2.1.2(k) Provide feeder location on main line disconnect 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Provide complete MCP 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Provide current tested fire extinguisher in elevator machine room 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not work, Re-inspection required 9/30/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the elevator machine room
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Perform the following tests to complete the Cat 5 full load test. Pull out and pull through force of govenor. Tripping speed of governor switch and governor jaws. Unintended movement. car safeties at rated speed with rated load. Re-inspection required 11/14/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display updated Missouri operating certificate in machine room. Top floor electrical room 10/30/2023