ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.15 - Multiple hoistways
|
2.1.1.4
|
x
|
|
RE-fire caluk the entire hoistway, every penatration.
|
2/28/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.2 - Car top light and outlet
|
2.14.7
|
x
|
|
Repair the non working light fixture at the top of the hoistway.
|
2/28/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.8
|
x
|
|
Remove the GFCI in the pit that the sump pump is connected to and replace it with a non protected circut.
|
2/28/2019
|
A17.1-2016 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Must post current Cert. of operation in Elevator Mach. room. CSR 40-5.100
|
1/28/2021
|