ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2.5 Sump pump shall be provided
|
x
|
|
A sump pump is required in the pit.
|
8/15/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.11 - Disconnecting Means and Control
|
2.26.4
|
x
|
|
The front of the disconnects in the machine space shall be flush with the controller to provide code required electrical clearance as specified in the NEC.
|
8/15/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.23 - Suspension rope
|
8.7.2.21
|
x
|
|
2.20.4 - Hoist ropes are 8mm and the minimum allowable size in 9.5mm. Customer to apply for a variance to allow undersized ropes.
|
8/15/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.23 - Suspension rope
|
8.7.2.21
|
|
|
2.20.4 - Hoist ropes are 8mm and the minimum allowable size in 9.5mm. Customer to apply for a variance to allow undersized ropes.
|
|