ASME A18.1-2005 : Lifts & Chairlifts
|
2.1 - Runways
|
2.1.3.8
|
x
|
|
Lower landing platform door does not open and shall be repaired.
|
|
|
Missouri Minimum : Platform Lifts
|
(U) - Existing Vertical and Inclined Platform Lifts
|
(U)1
|
x
|
|
Make the necessary adjustments to allow the unit to come completely down.
|
5/15/2019
|
|
Missouri Minimum : Platform Lifts
|
(U) - Existing Vertical and Inclined Platform Lifts
|
(U)1
|
x
|
|
Power cord is pulled out of the bottom of the disconnect box. Tie the excess cord out of the way so it does not pose a tripping hazard.
|
5/15/2019
|