Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Hoistway door to sill clearance over 3/4 in. 4/18/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Hoistway door to sill clearance over 3/4 inch. 3/12/2025
MO Minimum : Elevators (A) - Hoistways (A)16 Wiring in hoistway must be in approved conduit. 3/17/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)2 Cartop has water damage that lessens the capability to sustain the required 300 pound minimum load. 3/17/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)4 Accordion doors have split hinges allowing items to pass through during operation without interrupting operation, or opening the gate switch. 3/17/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x All 3 landing doors our outside of the 3/5 rule with regard to swing type landing doors. 3/17/2020
MO Minimum : Elevators (I) - Pits (I)7 Provide pit switch in pit. 3/17/2020
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)2 Car frame bent out of place. 3/17/2020
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Main hoisting cables badly rouged and worn. Replace. 3/17/2020
MO Minimum : Elevators (N) - Guide Rails (N)1 Car stabilizer rail bracket loose on cartop. 3/17/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency light and bell not working 3/4/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) MCP needed
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) MCP needed