Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate A current MO State operating certificate shall be posted near the equipment, in a noncombustible frame with a clear protective vision plate over it. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate A current MO State operating certificate shall be posted near the equipment, in a noncombustible frame with a clear protective vision plate over it.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 A start-up procedure shall be available to authorized personnel.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 A start-up procedure shall be available to authorized personnel. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.1 - General fire protection 6.1.1 x All construction around escalator shall be completed. 8/6/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.14 - Code data plate 8.9 An individual data plate shall be provided indicating the code to be used for inspections and tests. The data plate shall be in plain view, securely attached to each main line disconnect or controller. The current data plate is not in plain view, and is marked for A17.1 1996. It should be marked for A17.1 2005. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.14 - Code data plate 8.9 An individual data plate shall be provided indicating the code to be used for inspections and tests. The data plate shall be in plain view, securely attached to each main line disconnect or controller. The current data plate is not in plain view, and is marked for A17.1 1996. It should be marked for A17.1 2005.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.4 - Entrance and egress ends 6.1.3.6 x Finish upper landing floor. 8/6/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Inspection incomplete, need to perform the following tests to complete inspection: Upper comb plate testing & skirt indexing. Re-inspection required 9/26/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 6.1.7.2 x Lighting at lower level deck plate may be below 5 ft candles at night. 8/6/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 6.1.3.3.9 Step/Skirt Performance Index x Need index print out to complete inspection. Re-inspection required 3/13/2024
A17.1-2016 : Elevators 7.17 - Step/skirt clearances, panels, and performance index 6.1.3.3.5 Need index print out to complete report. 9/4/2024
A17.1-2016 : Elevators 7.3 - Handrails 8.6.8.15.13 Observed cracks in hand rail, right side. 8/2/2023
A17.1-2016 : Elevators 7.3 - Handrails 8.6.8.15.13 Observed cracks in hand rail, right side. Replace handrail required. 3/26/2024
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate. 3/26/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.14 - Code data plate 8.9 Post installation code data tag on unit. 11/3/2020
A17.1-2016 : Elevators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.15.1 Provide clean down of the unit. 3/26/2024
A17.1-2016 : Elevators 7.7 - Combplate and comb step impact device 8.6.8.4 x Provide comb impact test. 3/9/2023
A17.1-2016 : Elevators 7.19 - Maintenance records 8.6.1.2.1(a) Provide MCP. 3/26/2024
A17.1-2016 : Elevators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3.3 x Provide skirt index testing, record results. 3/9/2023
A17.1-2016 : Elevators 8.4 - Drive machine and brake 8.6.8.15.4 x Provide torque testing of unit brake. 3/9/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x Replace all broken step demarcation sections. There are at least 3 witnessed.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.4 - Drive machine and brake 8.6.8.12 Brake x The brake torque shall be tested. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x The demarcation light operation shall be tested. 9/12/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.2 x The handrail speed monitor shall be tested. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.4 (Hand rails) (Re-Inspection) x The handrails shall be inspected for wear and cracks. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.11 - Step level device 6.1.6.3.11 x The level step device shall be tested. 9/12/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.10 - Missing step device 6.1.6.5 x The missing step device shall be tested. 9/12/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3 Step/Skirt Performance Index x The skirt indexing test shall be performed. A test was performed which showed negative numbers for the loaded gap, which indicated the test was not performed properly. The test shall be repeated using the manufacturers instructions and requirements. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 x The step upthrust device shall be tested. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 6.1.3.6 x The upper comb impact horizontal center shall be tested. 9/29/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.14 - Code data plate 8.9 Verify that a nameplate or data plate that specifies the required brake torque and meets the requirements of A17.1 2005 6.1.5.3 has been provided. 9/29/2025