Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Need to re-program phone to call current elevator maintenance company or 24 hr security service. Re-inspection required 11/5/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test incomplete, no weights for Cat 5 test. Need to complete the following tests: 125% brake test, full load safeties, unintended motion up & down. Re-inspection required 11/5/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11 Periodic Inspection and Test. x Need to perform unintended movement testing. Re-inspection required 11/27/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.10 - Numbering of elevators, machines, and disconnect switches 8.11.2.1.2(j) Provide feeder location for mainline disconnect and 110v. Both located in top of hoistway. 9/22/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation Documents and parts on car top. Relocate. 9/22/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Supply on-site maintenance records. 10/29/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Need to provide specific written procedures for inspections & tests as part of MCP 11/5/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 2.20 Suspension electrical box at top of hoistway has error code flashing. Determine cause, repair as needed 9/22/2021