Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Need to provide written procedures for specific testing & inspections as part of the MCP
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test incomplete, no weights for Cat 5 tests. Need to complete the following tests to complete inspection: 125% brake test, full load safeties, unintended motion up & down. Re-inspection required
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Provide on-site maintenance records. 10/29/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Provide fire extinguisher. 10/29/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current operating certificate. 10/29/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation Documents and part on car top. Relocate. 9/22/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.11 - Disconnecting Means and Control 8.11.2.1.2(k) Provide feeder location for the mainline disconnect and 110v disconnect. Located at top of hoistway 9/22/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11 Periodic Inspection and Test. x Need to perform unintended movement test. Re-inspection required 11/27/2023
A17.1-2016 : Elevators 2.25 - Traction sheaves 2.20.8 x x Belt monitor shows bad belts and will not operate in auto. Must replace suspension means. Red-tagged, Re-inspection required 1/16/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Fire service needs to be tested. Re-inspection required 1/16/2025