ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Provide on-site maintenance records.
|
10/29/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.7 - Fire Extinguisher
|
8.6.1.6.5
|
|
|
Provide fire extinguisher.
|
10/29/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current operating certificate.
|
10/29/2020
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2 On-Site Documentation
|
|
|
Documents and part on car top. Relocate.
|
9/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.11 - Disconnecting Means and Control
|
8.11.2.1.2(k)
|
|
|
Provide feeder location for the mainline disconnect and 110v disconnect. Located at top of hoistway
|
9/22/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Need to provide written procedures for specific testing & inspections as part of the MCP
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.11 Periodic Inspection and Test.
|
x
|
|
Need to perform unintended movement test. Re-inspection required
|
11/27/2023
|
A17.1-2016 : Elevators
|
2.25 - Traction sheaves
|
2.20.8
|
x
|
x
|
Belt monitor shows bad belts and will not operate in auto. Must replace suspension means. Red-tagged, Re-inspection required
|
1/16/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Fire service needs to be tested. Re-inspection required
|
1/16/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test incomplete, no weights for Cat 5 tests. Need to complete the following tests to complete inspection: 125% brake test, full load safeties, unintended motion up & down. Re-inspection required
|
|